A new concept in comfort and equipment using a biomass heating system. The ideal solution for energy transition to renewable fuels.
Large DHW production with integrated stainless steel cylinder through accumulation | A buffer tank and a hopper all in one compact piece of equipment | Connectivity through smartphone.
The BIOCLASS IC DX product range is equipped with standard connectivity so the user can control the boiler and other installation components through the iConnect app, provided a WiFi network is available at the boiler installation site, with the following features:
· Starting up and shutting down the equipment.
· Choosing hot water and heating temperature set.
· Accessing information on use over time (consumption, ash pan filling status, etc.).
· Receiving alerts and suggestions.
· Programming equipment operating times, etc.
BIOCLASS IC boilers come with the “FLAME LOGIC” intelligent combustion control system, which constantly analyses flame quality and air flow to achieve optimal combustion of the biomass pellets.
The high quality of the materials used to manufacture the BIOCLASS boiler account for the 5-year warranty for the heat exchanger and 2-year warranty for the hydraulic and control components.
This boiler is equipped with full automatic cleaning of both the fume pipe heat transfer system (via a system of cams powered by a motor) and the burner (via a mobile base). Therefore, users do not have to worry about periodic boiler cleaning, except the annual cleaning performed by an authorised technical service. Automatic cleaning is performed without having to shut down the boiler, so users never go without heating and domestic hot water.
The ash generated by combustion is collected in the ash pan, which will have to be emptied when required, depending on consumption.
The ash emptying process can be extended by including a compressor ashtray (optional).
The BIOCLASS IC DX boiler comes fully equipped in a compact design.
Standard equipment includes a stainless steel DHW tank and integrated inertia buffer tank, a water flow pump, heating expansion vessel, DHW expansion tank and bleeders, among other components.
BIOCLASSIC IC DX boilers are also equipped with an innovative system to preheat return water. The HotStream system avoids the need for complicated mixing systems to prevent condensation caused by cold returns in the installation.
The reheating system can be used with direct returns to the boiler as high as 25º, thus allowing direct installation regardless of the type of hydraulic configuration of the installation.
There is also a wide range of optional hydraulic kits available to solve the most diverse home installation needs. All these kits are fitted with a regulating system that controls the flow temperature according to the exterior temperature, thereby optimising installation consumption. Among the various configurations that can be set up with these kits are underfloor heating systems for two areas with different flow temperatures.
CHARACTERISTICS | BioClass IC 18 DX | BioClass IC 25 DX |
---|---|---|
Fuel | Pellet | Pellet |
Rated power kW | 18 | 25 |
Performance at nominal power kW % | >92 | >92 |
Partial charge power Kw | 5,4 | 7,5 |
Performance partial charge power Kw % | >90 | >90 |
Boiler water volume L | 88 | 104 |
DHW production L/10 MIN Δ30ºC | 236 | 319 |
Continuous DHW production in L/H Δ30ºC | 666 | 830 |
Stainless steel cylinder L | 90 | 120 |
Energy efficiency class |
BioClass IC DX | |
---|---|
STAINLESS STEEL CYLINDER | |
CIRCULATION PUMP | |
DHW EXPANSION TANK | |
FLAME NO-RETURN SYSTEMN | |
ASH PAN | |
FEED WORM GEAR | |
AMBIENT TEMPERATURE PROBE | |
FAN MOTOR | |
SAFETY UNIT | |
DHW RECIRCULATION INTAKE | |
Coclea di alimentazione | |
SAFETY VALVE | |
FILLING GRILLE | |
BUFFER TANK | |
HEATING EXPANSION VESSEL | |
PRESSURE LIMITER | |
AIR PRESSURE SENSOR | |
BURNER | |
FILLING LOOP | |
AUTOMATIC BLEEDER | |
AUTOMATIC FUME PIPE CLEANING SYSTEM | |
DIELECTRIC SLEEVES | |
DRAIN VALVE | |
SIGHT GLASS |
BIOCLASS IC DX | Hopper
DC: Flow | DC': Optional flow | EA: DHW inlet | RC: Return | SH: Chimney connection | V: Drain valve | SA: DHW outlet |
MODEL | A | B | C | D | E | F | G | H | I | J | K | L | M | N |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BioClass IC 18 DX | 1590 | 545 | 920 | 1510 | 1315 | 1245 | 1185 | 770 | 200 | 45 | 100 | 270 | 85 | 195 |
BioClass IC 25 DX | 1590 | 670 | 1020 | 1510 | 1315 | 1245 | 1185 | 770 | 200 | 45 | 100 | 335 | 95 | 210 |
MODEL | X | Y | Z |
---|---|---|---|
Hopper DX S | 404 | 1590 | 920 |
Hopper DX L | 685 | 1590 | 920 |
-->