The FUSION TRIO HT all-in-one hydraulic module contains all the equipment required to install heating, cooling and domestic hot water with an integrated buffer tank.
The complete equipment included in the FUSION TRIO HT module makes it easier to install and takes up less space. Among the essential components of the equipment are the DHW safety unit, the DHW expansion tank, the three-way valve and the auxiliary boiler with resistance input.
FUSION TRIO HT DHW accumulators are made from stainless steel and meet the most demanding hygiene standards. The material’s high transmission coefficient also increases the accumulator’s capacity to produce domestic hot water.
Stainless steel has exceptional non-flaking, non-corrosion and non-sedimentation properties. A natural patina is formed on the surface that protects it from rust even in installations that use highly corrosive water.
The size of the coil heat exchanger in FUSION TRIO HT accumulators has been designed according to heat pump operating temperatures and flows to achieve maximum heat exchange and avoid discontinuous heat pump operating cycles.
This system keeps the entire accumulator at an even temperature so no cold areas are allowed, thereby preventing the formation of bacteria such as legionella.
El acumulador de agua caliente sanitaria del módulo FUSION TRIO HT está aislado térmicamente con espuma rígida de poliuretano inyectado en molde y disponen de una boca de acceso en la parte superior, la cual facilita la limpieza del interacumulador. A su vez incorpora una toma prevista para la resistencia eléctrica
MODEL | DHW VOLUME L | PRIMARY VOLUME L | APLICATION | DIMENSIONS: WIDTH | DIMENSIONS: HEIGHT | DIMENSIONS: DEPTH | EXCHANGE SURFACE m2 | ENERGY EFFICIENCY CLASS |
---|---|---|---|---|---|---|---|---|
FUSION TRIO HT 200/50 | 200 | 50 | Heating, Cooling and DHW | 600 | 1910 | 650 | 2,25 | |
FUSION TRIO HT 200/80 | 200 | 80 | Heating, Cooling and DHW | 600 | 1960 | 650 | 2,50 |
FUSION TRIO | |
---|---|
DHW inlet safety group | |
Dielectric sleeves | |
DHW expansion vessel | |
Stainless Steel DHW Cylinder | |
Desconector de llenado | |
Three-way valve | |
Filter | |
Buffer tank | |
Heating expansion vessel | |
Kit de resistance 1,5 kW FUSION | |
Kit de resistance 2,5 kW FUSION | |
Kit de resistance 3,5 kW FUSION | |
Back up kit pump | |
Back up insulation kit pump | |
Cathodic protection | |
Outdoor unit silent blocks kit |
FUSION HE
IC: Heating/Cooling inlet | RC: Heating/Cooling Return | IBC: Heat Pump inlet | RBC: Heat Pump Return | DHW: DHW flow |
DCW: DCW inlet | R: DHW Recirculation inlet | IAC: Auxiliary boiler inlet for heating | RAC: Auxiliary boiler return for heating |
FUSION TRIO 200/50 (mm) | FUSION TRIO 200/80 (mm) |
---|
Total Height A | 2028 | 2088 |
Inlet heights B | 1980 | 2040 |
Inlet heights C | 1914 | 1974 |